Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
The Effects of Enamel Matrix Derivative and Cyclic Mechanical Strain on Human Gingival Fibroblasts in an In Vitro Defect Healing Model
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 31 , Issue 6
November/December 2011

Pages 671-678


The Effects of Enamel Matrix Derivative and Cyclic Mechanical Strain on Human Gingival Fibroblasts in an In Vitro Defect Healing Model

Jill E. Sanders, DDS/Augustine Chuang, PhD/Gary D. Swiec, DDS/Fredrick C. Bisch, DMD/Robert W. Herold, DDS/Thomas B. Buxton, PhD/James C. McPherson III, PhD


PMID: 22140669
DOI: 10.11607/prd.00.1026

Gingival fibroblasts (GFs) play a considerable role in the maintenance of the gingival apparatus as well as in connective tissue repair. Mobility of a periodontal wound or soft tissue graft can impair connective tissue healing from the GFs. Enamel matrix derivative (EMD) is an enamel matrix protein used clinically for periodontal regeneration of intrabony defects and furcations, as well as treatment of gingival margin recessions. The goal of this project was to compare the effects of varying concentrations of EMD, with and without cyclic mechanical strain, on cellular wound fill of human GFs using an in vitro defect healing model. GFs were seeded and cultured in six-well flexible-bottomed plates. A 3-mm wound was created in the central portion of each confluent well. Three wells were treated with each EMD concentration of 0 µg/mL (control), 30 µg/mL, 60 µg/mL, or 120 µg/mL. The plates were placed in an incubator containing a strain unit to subject test plates to cyclic strain. An identical set of control plates were not flexed. Cells were examined on days 4, 8, 12, and 16. Microphotographs were taken and wound fill measurements made using image analysis software. The percent wound fill was calculated. All nonflexed plates, regardless of EMD concentration, reached > 90% defect fill at similar rates by day 16. However, in the flexed plates, EMD had a significant negative effect on defect fill. The defect fill was 55.7% for 0 µg/mL EMD, 48.2% for 30 µg/mL EMD, 36.7% for 60 µg/mL EMD, and 34.1% for 120 µg/mL EMD on day 16 for the flexed GFs. EMD, in concentrations as high as 120 µg/mL, did not significantly affect the amount of defect fill with nonflexed GFs. However, when the GFs were flexed, the addition of EMD had a significant negative effect on defect fill in a dose-dependent manner. (Int J Periodontics Restorative Dent 2011;31:671–678.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help